Electrolux 42 설치, 사용 및 관리 매뉴얼 - 페이지 8
{카테고리_이름} Electrolux 42에 대한 설치, 사용 및 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Electrolux 42 22 페이지. 30” and 36” free-standing range hood
Electrolux 42에 대해서도 마찬가지입니다: 사용 설명서 및 설치 지침 (45 페이지)
Installing the hood
8
Examples of possible ducting
Ductwork installation guidelines
For safety reasons, ducting should vent directly
outdoors (not into an attic, underneath the house,
into the garage or into any enclosed space).
Keep duct runs as short and straight as possible.
Duct fittings (elbows and transitions) reduce air flow
efficiency.
Back to back elbows and "S" turns give very poor
delivery and are not recommended.
A short straight length of duct at the inlet of the
remote blower gives the best delivery.
Transition to duct from the integral blower or remote
duct transition as close to the downdraft as is pos-
sible.
In order of preference, use
1st. 10" round duct
2nd. 8" round duct
3rd. 3-1/4" x 14" duct
4th. 7" round duct
5th. 3-1/4" x l0" duct
6th. 6" round duct
The use of flexible metal round duct should only be
used when no other duct fitting exists. Limit use to
short lengths and do not crush when making
corners
Roof pitch w/
flashing and cap
Pipe
Pipe
Transition
Transition
Vertical discharge
Deflector
Pipe
Transition
Sidewalk cap w/
gravity damper
Recirculating
Ductwork and wiring locations
•
Determine the exact location of the vent hood.
•
Locate the template packed with the literature.
•
The height installation is determined by the
following image. Mark the location.
•
Installation height: 30" gas cooktop/range or 24"
to 30" electric cooktop/range.
Sidewalk cap w/
gravity damper
•
Use a level to draw a horizontal straight pencil line
on the wall, which is your desired
installation height.
•
Find the centerline of the cooktop. Use a level to
draw a vertical straight pencil line on the wall.
CHECK TO BE SURE THE LINE IS PERFECTLY
PERPERNDICULAR.
Installation height