Andrew HELIAX HJ11-50 설치 지침 - 페이지 4
{카테고리_이름} Andrew HELIAX HJ11-50에 대한 설치 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Andrew HELIAX HJ11-50 4 페이지. Coaxial cable
16
Drill through 4 insulator
guide holes with 3/16"
(4.7 mm) drill for gas-
pass operation
17
Notice
The installation, maintenance, or removal of antenna
systems requires qualified, experienced personnel.
Andrew installation instructions are written for such
personnel. Antenna systems should be inspected once
a year by qualified personnel to verify proper installa-
tion, maintenance, and condition of equipment.
Andrew disclaims any liability or responsibility for the
results of improper installation practices.
Andrew Corporation
10500 West 153rd Street
Orland Park, IL U.S.A. 60462
Place flare ring on insulator
and screw stud into stub so
that pin enters stub slot
Hold insulator and tighten
stud torqued to a range of
20-45 lb f -ft (27.1-61 N·m)
Telephone: 708/349-3300
FAX (U.S.A.): 1-800/349-5444
TELEX: 25-3897
Place 2 O-rings on helix ring and 1 O-ring on
18
insulator. Apply silicone grease to O-rings
and gasket and slide body into place.
19
Use 3 long screws, equally spaced, to pull
parts together. Add short screws then
replace long screws with short screws, and
tighten screws to 6-8 lb f -ft (8.1-10.8 N·m)
Want Andrew to attach connectors for you? Call us.
Skilled personnel at Andrew can attach connectors for
you, quickly and economically. Every factory-made
cable assembly is 100% tested before shipment and
has a 3-year warranty. For details about this service,
contact Andrew.
Customer Service, 24 hours: U.S.A. • Canada • Mexico: 1-800/255-1479
U.K.: 0800 250055 • Republic of Ireland: 1 800 535358
Other Europe: +44 592 782 612
Male
Female
Printed in U.S.A.9/95
Copyright © 1995 by Andrew Corporation