Electrolux C240R 서비스 매뉴얼 - 페이지 29

{카테고리_이름} Electrolux C240R에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Electrolux C240R 41 페이지. Hydro-extractor
Electrolux C240R에 대해서도 마찬가지입니다: 운영 매뉴얼 (24 페이지), 운영 및 설치 매뉴얼 (20 페이지)

Electrolux C240R 서비스 매뉴얼
Service
manual

Component units

(230V 50 Hz; 400- 415V 50 Hz and 440V 60 Hz)
1
K1
Relay, extraction
K2
Relay, brake
T1
Auxiliary transformer - supplies power to the electronics unit, and provides
control voltage 24 V AC to components. The transformer is switchable for mains
voltages: 230 V, 400 V, 415 V and 440 V.
F1
Precision fuse M 0.2 A/500 V - protects primary side of auxiliary transformer.
F2
Precision fuse T 2.5 A/500 V - protects secondary side of auxiliary.
SW1
Microswitch - detects position of lid lock.
CP
Control panel with push-button and indicator lights.
Y1
Lock magnet - operate the lid lock.
MP
Circuit board.
X1
Terminal connection.
1
CP
MP
F2
T1
F1
487 03 29 91

21. Automatic unit

21
Y1
Lid lock
SW1
K2
K1
X1
21.1