OPERATING CHARACTERISTICS
Roots RCS blowers, as covered in this manual, are
available in basic frame size of 4Y2 inch gear diameter.
Within this frame size are two case lengths, selected to
produce reasonable steps in blower carJacity ratings. All
units are designated as air blowers, and may be used for
handling air in either pressure or vacuum service. They
are unsuitable for handling gases because shaft seals are
not designed to prevent leakage to atmosphere.
The basic Roots rotary lobe blower is a positive
displacement type unit, whose pumping capacity is deter-
mined by size, operating speed and pressure conditions. It
employs two double-lobe impellers mounted on parallel
shafts and rotating in opposite directions within a
cylinder closed at the ends by headplates. As the impellers
rotate, air is drawn into one side of the cylinder and forced
out the opposite side against the pressure existing there.
The pressure developed,
therefore, depends on the
resistance of the discharge system.
Effective sealing of the blower inlet area from the
discharge area is accomplished by use of very small
operating clearances. Resulting absence of moving con-
tacts eliminates the need for any internal lubrication.
Clearance between the impellers during rotation are main-
tained by a pair of accurately machined timing gears,
mounted on the two shafts extended outside the blower
casing.
Operation of the rotary lobe blower is illustrated in
FIGURE 1, where air flow is right to left from inlet to
discharge with the lower impeller rotating clockwise. In
Position 1 it is delivering a known volume (A) to the
discharge, while space (B) between the upper impeller and
cylinder wall is being filled. Counterclockwise rotation of
this impeller then traps equal volume (B) in Position 2,
and further rotation delivers it to the discharge in Posi-
tion 3. At the same time, another similar volume is form-
ing under the lower impeller, and will be discharged when
rotation reaches Position 1 again.
One complete revolution of the driving shaft alter-
nately traps four equal and known volumes of air (two by
each impeller) and pushes them through to the discharge.
The pumping capacity of a lobe blower operating at a con-
stant speed therefore remains relatively independent of
reasonable inlet or discharge pressure variations. To
change capacity, it is necessary either to change speed or
rotation or vent some of the air.
No attempt should ever be made to control capacity
by means of a throttle valve in the intake or discharge pip-
ing. This will not only increase the power load on the
driver, but can also overload and seriously damage the
blower. If a possibility does exist that flow to the blower
inlet may be cut off during normal operation of a process,
then an adequate vacuum relief valve must be installed
near the blower. A pressure type relief valve in the
discharge line near the blower is required for protection
against cut-off or blocking in this line. See Figure 2.
When a belt drive is employed, blower speed can
usually be adjusted to obtain desired capacity by dhang-
ing the diameter of one or both sheaves. In a direct
coupled arrangement a variable speed motor or transmis-
sion is required, or excess air may be blown off through a
manually controlled unloading valve and silencer. If
returned to the blower inlet, the air must be cooled to
100 OF (38°C) through a by-pass arrangement to maintain
acceptable blower temperatures.
Before making any change in blower capacity, or
operating conditions, contact the nearest Sales Office for
specific information applying to your particular blower.
In all cases, operating conditions must be maintained
within the approved range of pressures, temperatures and
speeds as stated under LIMITATIONS. Also, the blower
must not be used to handle air containing liquids or solids.
Serious damage to the rotating parts will result.
OPERATING LIMITATIONS
To permit continued satisfactory performance, a
Roots RCS blower must be operated within certain ap-
proved limiting conditions. The Manufacturer's warranty
is, of course, also contingent on such operation.
Maximum limits for pressure, temperatures and
speed are specified in Table 1 for RCS blowers. These
limits apply to all blowers of normal construction, having
operating clearances as listed in Table 5, when operated
•
POSITION 1
POSITION 2
POSITION 3
K
~207'J
Figure 1 :- Flow Through ReS Blower
2