{카테고리_이름} Atlantic Alfea Series에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Atlantic Alfea Series 16 페이지. Alféa s series heat pump air/water split, single service

Split system
Line
Function
Diagnostics heat generation
8410
Return temp HP
Setpoint (return) HP
8412
Flow temp HP
Setpoint (flow) HP
8413
Compressor modulation
Diagnostics consumers
8700
Outdside temperature
8701
Outside temp min
Reset ? (No, Yes)
8702
Outside temp max
Reset ? (No, Yes)
8740
Room temperature 1
Room setpoint 1
8743
Flow temperature 1
Flow temperature setpoint 1
8756
Flow temp cooling 1
Flow temp setpoint cooling 1
8770
Room temperature 2
Room setpoint 2
8773
Flow temperature 2
Flow temperature setpoint 2
8830
DHW (domestic hot water) temperature
DHW temperature setpoint
8900
Swimming pool temperature
Swimming pool temperature setpoint
- 14 -
Setting range
or display
0... 140 °C
0... 140 °C
0... 140 °C
0... 140 °C
0... 100%
-50... 50 °C
-50... 50 °C
-50... 50 °C
0... 50 °C
4... 35 °C
0... 140 °C
0... 140 °C
0... 140 °C
0... 140 °C
0... 50 °C
4... 35 °C
0... 140 °C
0... 140 °C
0... 140 °C
5... 80 °C
0... 140 °C
0... 35 °C
Setting
Basic
increment
setting
20 °C
20 °C
50 °C
50 °C
0 °C
0 °C
20 °C
20 °C
50 °C
50 °C
50 °C
22 °C
Operation manual "1328 - EN"