Atlantic STEATITE 886089 설치 및 사용 설명서 - 페이지 6

{카테고리_이름} Atlantic STEATITE 886089에 대한 설치 및 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Atlantic STEATITE 886089 17 페이지. Electric storage water heater, mains pressure electric storage water heaters 150/200/250/300 litre

Atlantic STEATITE 886089 설치 및 사용 설명서
DN15 copper drain lines must be connected to the discharge pipe of the
PTR valve. The copper drain line must fall away from the ESWH and be
installed in a frost- free environment.
The termination point of a drain line must comply with the requirements of
AS/NZS 3500.4
 
WARNING: The Pressure Temperature Relief valve and drain line must not
be sealed or blocked.

Electric Connection

All electrical work must be carried out by a registered electrician and in
accordance with AS/NZ 3000.
The Atlantic ESWH must be filled with water before connection to a power
supply.
Switch off the power before removing the cover to avoid any risk of injury or
electric shock.
The installation must be equipped, upstream of the appliance, with a
bipolar cut-out device (fuse, breaker switch) respecting local regulations
(30 mA earth-leakage breaker).
Always connect the earth conductor of the cable to the earth ground wire or
connect the earth conductor to the appropriate terminal identified by the
symbol.

Thermal cut-out

All Atlantic ESWH are equipped with a thermal cut-out with manual resetting
which shuts off the power to the water heater if it becomes overheated.
If the circuit breaker keeps tripping,
a) Switch off the power before taking any further action,
b) Remove the cover,
c) Check the electrical connections,
6