AirTech ATS-100 사용자 설명서 - 페이지 8

{카테고리_이름} AirTech ATS-100에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AirTech ATS-100 8 페이지. Land mobile radio

Charger and Battery

1. Battery (Li-ion)
Voltage
Duty time (5-5-90)
2. Charger
Input power
Operating temperature
Connect the charger to an appropriate outlet (90~250 VAC).
Turn the transceiver power off and place the radio into the
front socket of the charger. The red light illuminates during
charging and the green light comes on when the charge is
complete. When you place two batteries in the charger at the
same time, the front battery will charge first. The rear battery
will begin charging when the front battery charge is complete.
Red
On
Charging
Blinking
Abnormal battery
Green
On
Fully charged
Orange
On
Stand-by for charging (rear cup)
Blinking
Discharging
When you put a battery in the rear cup of the charger the
charger checks the voltage. If voltage is over 7.4V, the
charger starts discharging for 4 minutes then checks
again. If voltage is still more than 7V, it discharges until
the voltage is 6V then starts charging.
DC 7.5V
Over 10 hrs
(90~250VAC)
10-30 deg. C
5