Outdoor Unit Installation Drawings
1.
Precautions for humidifying hose installation work.
• Moisture on the outdoor unit is brought to the indoor unit together with air around the outdoor unit during humidifying
operation. Install the outdoor unit in a clean and calm location.
• Be sure to use the humidifying hose sold as an optional accessory. (KPMH996A10S (10m set), KPMH996A15S (15m set))
CAUTION
Do not connect the embedded branch piping and the outdoor unit when only carrying out piping work without connecting the
indoor unit in order to add another indoor unit later.
Make sure no dirt or moisture gets into either side of the embedded branch piping.
See "Precautions for Laying Refrigerant Piping" on page 9 for details.
Installation of humidifying hoses, respectively, in upward direction in ROOM A and in downward direction
in ROOM B.
<Front side>
Allow 300mm of
work space below
the ceiling surface.
Wire
If there is the danger of the unit
falling or overturning, fix the unit
with foundation bolts, or with wire
or other means.
3
ROOM A
ROOM B
Level mounting base
(available separately)
If the location does not have good drainage,
place the unit on a level mounting base (or a
plastic pedestal). Install the outdoor unit in a
level position. Failure to do so may result in
water leakage or accumulation.
Humidifying hose
Stop valve cover
Also insulate the connection on the outdoor unit.
Use tape or insulating material on all connections
to prevent air from getting in between the copper
piping and the insulation tube.
Be sure to do this if the outdoor unit is installed
above.
<Back side>
Humidifying hose
ROOM A
unit: mm
Clamping material
Insulation tube
Tape
Stop valve cover
Humidifying hose
ROOM B
■English