General Use Criteria
Use only clean, dry air. If moisture is present please use a liquid separator.
x
Do not use flammable, explosive gases or atmosphere that contains such gases with standard motors/blowers. It is required
x
that you consult Atlantic Blowers for explosion proof motors/blowers.
Ambient temperatures must be between 0°C – 40°C (32° F – 104°F). For higher temperatures please consult factory.
x
Protect unit from contaminants and moisture.
x
Protect all surrounding items from exhausted air, as it can be very hot. It is strongly recommended that the first 5'-8' of
x
piping be metal.
Air particles, water vapor, oil based contaminants or other liquids, can be harmful to the blower and may cause over-heating.
x
The use of an air-filter, relief valve, and pressure gauge are highly recommended in conjunction with our blowers.
When using the blower at a high altitude or high temperatures, please consult with Atlantic Blowers prior to use.
x

Safety Notice

To ensure safe operation, we have provided many important safety guidelines in this manual for the Atlantic Regenerative Blower.
Please read this instruction manual carefully, and pay particular attention to instructions with the following signs:
DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury

1-1 Installation

Install the blower on a level, stable operating surface and use vibration isolation pads to reduce noise and
vibration.
1.
Correct installation is the customer's responsibility.
2.
Recommended piping should be, at minimum, the same size as the inlet and outlet ports.
3.
Elbows increase friction. Minimizing the amount of elbows in the piping run will decrease friction loss.
4.
Pressure or relief valves should be installed in a "T" that is at least one (1) pipe size larger than the port diameter.
5.
Exhaust air temperature increases significantly above 65" of water column. Discharged air is typically too hot for most
plastic piping. Therefore, metal piping is recommended for at least the first five (5´) to eight (8´) feet from the blower on
the discharge side. In addition, this piping MUST be guarded and marked "DANGER-HOT-DO NOT TOUCH."
6.
Install the blower in a location protected from the elements, or use an enclosure to protect the unit.
1-2 Rotation
From the motor side of the blower, verify the blower is rotating in the direction indicated by the arrow on the motor. (The motor
side is marked with an arrow on most models.) Proper rotation can also be checked by the air flow at the inlet and outlet ports.
On blowers powered by a 3-phase motor, change the connection of any two (2) wires to reverse blower rotation.
.