9). IDENTIFICATION OF SPARE PARTS
Heating element 2kW (for 6kW RELAX)
Heating element 3kW (for 9 & 18kW)
Heating element 4kW (for 12 & 24kW)
Set of 5 gaskets
Power relay
Main Circuit Breaker
Limit thermostat
Controller XT120C
Temperature sensor
10). FAULT DETECTION
Be sure to switch off the boiler, whilst examining any component fault
FAULT
Control panel lights are off
The control panel screen is off
Check circuit breaker 11 position
The pump does not revolve
If the fault persists
Description
(KA1 – KA2)
(11 – 12)
Check power to the immersion heater
couplings
Check fuse F1 is sound & the limit
thermostat is set
Check fuse F2
Call in a qualified engineer
Code
790 082
790 083
790 084
2565
582 062
585 003
581 104
583 042
583 024
ACTION
13