Floor surface
The floor at the installation site must not give. Reinforce
the floor if necessary.
The appliance is very heavy. The weight when empty is
detailed in the table below.
Model
KDD65
KDD75
Wall clearance
If the appliance is positioned in the corner of a room or
a recess, minimum clearances at the sides must be
maintained so that the heated air is able to escape
unimpeded and the appliance doors can be fully
opened.
Model
A
B
KDD65
1416 mm 1428 mm 600 mm
KDD75
1487 mm 1536 mm 600 mm
Weight
87 kg
98 kg
W
C
790 mm
860 mm
Observe the room temperature and
ventilation requirements
Room temperature
The appliance is designed for a certain climate class.
Depending on the climate class, the appliance can be
operated at the following ambient temperatures.
The climate class is specified on the rating plate.
Climate class
Permissible room temperature
+10 °C to 32 °C
SN
+16 °C to 32 °C
N
+16 °C to 38 °C
ST
+16 °C to 43 °C
T
Note
The appliance is fully functional within the room
temperature limits of the specified climate class. If an
appliance in the SN climate class is operated at lower
ambient temperatures, damage to the appliance can be
excluded up to a temperature of +5 °C.
Ventilation
The heated air must be able to escape unimpeded.
Otherwise, the refrigerating unit has to work harder,
which increases the appliance's power consumption.
Therefore, never cover over or block the air vent.
en
5