2 Save Energy Owl Intuition-PV 시작하기 - 페이지 6

{카테고리_이름} 2 Save Energy Owl Intuition-PV에 대한 시작하기을 온라인으로 검색하거나 PDF를 다운로드하세요. 2 Save Energy Owl Intuition-PV 12 페이지. Electricity consumption & solar pv generation monitoring - single phase, for homes fitted with solar pv

mitter left hand socket.
Locate the PV generated power cable between the Henley Block and Gen-
eration meter / Inverter. Using the latch, clamp the second Sensor around
the insulated Live cable going into the Henley Block. Plug this Sensor into
the Transmitter centre socket.
The Sensors must be a loose fit onto the cables.
The Transmitter should be hung on the wall in a free area as far from
large metal objects as possible.
Type 2 Wiring: If your Solar PV feed is straight into your Consumer Unit /
Distribution Panel (Type 2 wiring arrangement) then you will need both the
Intuition-pv kit and a Y-Cable Pack (Part Number: TSE200-010) available from
www.theowl.com. Follow the additional instructions with that pack regarding
attaching the Sensors.
Domestic
Loads
Consumer Unit
Ring Mains,
Lights,
Cooker etc
Live
(Brown or Red
normally covered
with Grey sheath)
Type 2 - Intuition-pv - Y-Cable Pack also required
6
Solar PV
Array
DC
Grid-tie
Inverter
PV Generation
240V AC
Sensor 1
50Hz
WARNING
- RISK OF ELECTRICAL SHOCK
- Please Refer to User Manual.
WARNING
- RISK OF ELECTRICAL SHOCK
- Please Refer to User Manual.
PV Gen
Sensor 2
Fuse Box /
WARNING
- RISK OF ELECTRICAL SHOCK
- Please Refer to User Manual.
Grid
Sensor
Transmitter
Utility
Meter
© 2 Save Energy Limited 2012
Y-Cable
Electricity
Grid