DRIZAIR 2400 DEHUMIDIFIER TROUBLESHOOTING
PROBLEM
Unit continuously in defrost
Unit not defrosting (heavy
frost or ice buildup that pers-
ists over several hours)
Little water is being collected
by the unit
Pump not functioning
properly
COPYRIGHT © DRI-EAZ PRODUCTS, INC. 1998
CAUSE
1. Defective control
assembly
2. Room temperature is too
low
3. Defective bypass relay
valve
1. Defective control
assembly
2. Sensor defective
3. Defective bypass relay
valve
1. Room air has been dried
to 45% Rh
2. Room temperature is too
low
3. Air movement through
unit restricted
1. Stuck float valve
Dri-Eaz Service Department (360) 757-7776
10
continued
SOLUTION
AST
1. Replace control assembly
FS
2. Increase the room tempera-
AST
ture
3. Replace bypass valve
AST
1. Replace control assembly
AST
2. Replace sensor
3. Replace bypass valve
AST
FS
1. Check humidity with a hy-
grometer
FS
2. Increase the room tempera-
ture
FS/
3. Increase airflow or clean out
AST
coils
FS
1. Clean float valve shaft