SAFETY PRECAUTIONS
CA
CA
CAUTION
UTION
UTION
UTION
CA
CA
UTION
!
• For general ventilating use only. Do not use to exhaust hazardous or explosive
materials and vapors.
• To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do
not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces
or garages.
• This blower assembly is approved for use with the following Electrolux retractable
ventilation systems: E30DD75ESS, E36DD75ESS, E46DD75ESS and E48DD75ESS
only. Use of this blower assembly with any other product or in any other
configuration is hazardous and voids the product warranty.
NO
NO
NO
NO
NOTES
TES
TES
TES
TES
• Consult a licensed ventilation contractor or qualified technician for proper
installation of exhaust ducting.
• Locate the cooking area for minimum cross drafts – away from doors and windows,
when possible.
• Ducts must be of adequate size and duct runs should be as short and straight as
possible. Where turns are necessary, keep turning radius as large and smooth as
possible.
• The ducting must be air tight. Use a minimum of 2 sheet metal screws at every duct
joint. Then, seal the duct joints with a high quality duct tape.
• In duct runs less than 10 equivalent straight feet, the remote blower may interfere
with the cooktop burner performance due to the high volume of air moved. An
adjustable damper (not included) should be installed in the ducting system. The
damper can be adjusted so that proper ventilation and cooktop burner
performance is achieved.
• Installation of duct work should be carefully planned if it is to go under a concrete
slab floor. The duct trench should be boxed to prevent collapse from the wet
cement. Be sure to allow room to run the electrical wiring and conduit.
5
Safety