only. The internal tank has a 9.3-gallon capacity. Do
not overfill.
Attaching the flue to the Dragon
The Dragon is designed to operate with the flue
attached to the top of the unit. Always operate the
Dragon with the flue attached. In addition to preventing
any water or debris from falling into the heat
exchanger, the flue creates a slight draft on the
Dragon exhaust that assists in preventing thermal
overload.
1. To attach the flue, slide it over the pipe on top of
the heat exchanger.
Attach the flue to the Dragon
2. Drill two 1/8-inch holes through the bottom of the
flue into the heat exchanger pipe. The holes
should be approximately 90 degrees apart.
Drill two 1/8-inch holes in the flue
07-00407F 02/2008
3. Drive a sheet metal screw (#8x1) through each
hole to secure the flue to the Dragon.
Secure the flue to the Dragon with sheet metal screws
Attaching ducting to the Dragon
The Dragon delivers clean heat to a structure through
two 30-foot lengths of 8-inch diameter aluminum
ducting. You must attach both lengths of ducting to the
Dragon for operation.
1. Extend a 1-foot section of ducting and slide a
hose clamp over the end. Slip the ducting over
one of the Dragon outlet duct rings. Secure the
ducting firmly to the duct ring with the hose clamp.
Make sure the clamp is tight enough to hold the
ducting in place when you extend it to the
structure.
Clamp the ducting securely to the duct ring