Lamp Installation or Replacement BIO-1.5 and BIO-3.0 using ballast no.10-
0518A 120v 50/60Hz and using ballast no.10-0514A 230v 50/60Hz
Figure 4 – Lamp Replacement for BIO-1.5
and BIO-3.0 (ballast no 10-0518A or 10-0514A)
Step 2 - Remove End-Cap
1.
Remove EASY-OFF
2.
3.
Pull lamp cord and carefully withdraw lamp approximately 2 inches from chamber. While holding lamp
end, remove lamp socket from exposed lamp end.
4. Carefully withdraw lamp from chamber. Be sure to withdraw lamp straight out without angling
until completely clear of quartz sleeve.
Lamp and quartz sleeve are easily damaged. Exercise care when handling.
5. Reinstall lamp in reverse order.
Germicidal ultraviolet rays are harmful to eyes and skin. Do not restore power to water purifier until
lamp and both EASY-OFF
10
IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY
EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.
Disconnect power to water purifier, and remove ground connector from the chamber.
End Cap by pulling cap off static gland nut.
TM
End Caps have been properly reinstalled.
TM
Step 3 - Remove Socket
Step 1 - Disconnect Power to Water
Purifier and Remove Ground Connector
Step 4 - Remove Lamp