Recommended System Maintenance:
Maintenance recommendations listed below are based upon a normal installation. Maintenance requirements may
vary from site to site depending upon unit used and installation environment.
1) Compressors:
We recommend compressor vanes be replaced at least once per year of operation. (See Price Schedule for specific
part number and cost for the Compressor Vane Kits).
2) Aeration Tubing:
Aeration tubing should be cleaned off with a rag if flow ever appears non-uniformed on the Pond's surface. This
can be done by removing the tubing from the pond and wiping off the tubing. This task can be performed from
either on shore or on board a boat.
3) Ozone Cell Lamp:
We recommend that the lamp be replaced every 10,000 hours of operation. (See Price Schedule for specific part
number and cost for the Ozone Cell Lamp).
4) Electrostatic Air In-Take Filter:
We recommend the filter be inspected once every 30 days for dirt build-up. The filter can be cleaned using soap
and water. Replacement is necessary when cleaning the filter can no longer can be achieved or the filter material
breaks down. (See Price Schedule for specific part number and cost for the In-Take Air Filter).