Atlantic Ultraviolet Mighty Pure MP36C 소유자 매뉴얼 - 페이지 13
{카테고리_이름} Atlantic Ultraviolet Mighty Pure MP36C에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Atlantic Ultraviolet Mighty Pure MP36C 20 페이지. Ultraviolet
Atlantic Ultraviolet Mighty Pure MP36C에 대해서도 마찬가지입니다: 소유자 매뉴얼 (20 페이지)
TROUBLESHOOTING
!
CAUTION:
IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel.
Problem
Purifier not operating.
Water leaking into/from
purifier.
Poor purifier performance
AND/OR Low UV intensity
(As indicated on Optional
Guardian™
Ultraviolet Monitor).
Always disconnect power to the water purifier, before performing any service.
Table 3 - Troubleshooting
Possible Cause
No electrical power...
Ballast
Lamp-out Protection
(MP16A, MP22A & MP36C) two (2) minutes to reset.
Cracked or broken
quartz sleeve...
Quartz sleeve sealing
o-ring (s) worn, damaged...
Poor, or loose, connections
or fittings...
Quartz sleeve fouled...
Sensor Probe, if equipped,
lens fouled...
Germicidal lamp output
depreciating...
Germicidal lamp not
functioning...
Low input voltage...
Change in water quality...
Corrective Action
Verify that the purifier is connected to a live power source.
Disconnect the purifier from utility power. Replace lamp.
The purifier must remain disconnected from power for
Shut down purifier, drain, and replace quartz sleeve.
See "Quartz Sleeve Cleaning or Replacement" in the
"Maintenance" section.
Shut down purifier, drain, and remove static gland nut,
replace sealing o-ring. See "Quartz Sleeve Cleaning or
Replacement" in the "Maintenance" section.
Tighten suspect connection or fitting; or shut down
purifier, drain, and remove fitting or connection.
Clean threads; reapply thread sealing tape and reinstall.
Clean quartz sleeve, see "Quartz Sleeve Cleaning
or Replacement" in the "Maintenance" section.
Clean lens or Quartz Rod, see "Optional Ultraviolet
Monitor Sensor Probe Cleaning" in the "Maintenance"
section.
Replace lamp, as it nears its end of life (EOL). See
"Lamp Replacement" in the "Maintenance" section.
Replace lamp. See "Lamp Replacement" in the
"Maintenance" section.
Verify input voltage to purifier.
Have water tested to confirm that it does not exceed
maximum recommended concentration levels for use
with this purifier.
13