Atlantic Ultraviolet MIN-1 소유자 매뉴얼 - 페이지 11
{카테고리_이름} Atlantic Ultraviolet MIN-1에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Atlantic Ultraviolet MIN-1 16 페이지. Ultraviolet water purifiers
Atlantic Ultraviolet MIN-1에 대해서도 마찬가지입니다: 소유자 매뉴얼 (16 페이지)
Q
S
I
UARTZ
LEEVE
NSTALLATION
120v 50/60Hz (ballast no. 10-0508B) or 230v 50/60Hz (ballast no. 10-0504B)
120v (shown)
Step 4 - Remove Gland Nuts
SAFETY EQUIPMENT REQUIRED TO PERFORM TASK
1.
WARNING: Disconnect power to water purifier.
•
For 120v 50/60Hz version using ballast no. 10-0508B or 230v 50/60Hz version using ballast no. 10-0504B remove
the ground connector from the chamber, and go to the next step.
2.
Shut off water supply to water purifier via inlet and outlet shut off valves and drain chamber, if possible.
3. Follow the steps in "Lamp Installation or Replacement" to remove lamp.
CAUTION: Lamp and quartz sleeve are easily damaged. Exercise care when handling.
4.
Unscrew static gland nuts from each end of the chamber. Avoid striking quartz sleeve with static gland nut.
5.
Remove Teflon
washer and o-ring from both ends of quartz sleeve. Teflon
®
gland nut. If so, remove Teflon
6. Carefully remove quartz sleeve from chamber. NOTE: It is advisable to support the quartz sleeve on the opposite end
with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber.
7. Once the quartz sleeve is removed, clean with alcohol or a mild, non-abrasive detergent. Stubborn stains usually can be
removed with a dilute hydrochloric acid.
NOTE: Follow all manufacturer's instructions and precautions when handling chemicals.
8. Reassemble in reverse order. Make sure the quartz sleeve protrudes an equal distance past each threaded nipple. Be sure
o-rings are placed on quartz sleeve before Teflon
9. Tighten static gland nuts firmly by hand only, DO NOT USE HAND TOOLS. Tightening with hand tools is likely to cause
quartz sleeve to break.
10. Slowly restore water supply to water purifier and check for leaks.
11. If no leaks occur, reinstall lamp, following the steps in "Lamp Installation or Replacement" section.
WARNING: Germicidal ultraviolet rays are harmful to eyes and skin. Do not restore power to water purifier until
lamp and both EASY-OFF
C
LEANING OR
Figure 5 - Quartz Sleeve Installation, Cleaning or Replacement
120v (shown)
Step 5 - Remove Washer & O-Rings
washer from static gland nut before proceeding.
®
washer.
®
end caps have been properly reinstalled.
TM
R
EPLACEMENT
washer will sometimes remain within the static
®
120v (shown)
Step 6 - Remove Quartz Sleeve
11