Step 1
Install Nut on Stud
10.
unprotected 3-prong receptacle is encountered, it must be replaced by a properly grounded Ground Fault Circuit Interrupt
(GFCI) receptacle. Installation must be in accordance with the National Electrical Code and any local codes and ordinances by
a qualified Electrician.
11. Prior to completing the plumbing connection to the water purifier, it is recommended to disinfect the "downstream" plumbing
between the purifier and point of use. This is done by introducing chlorine or other disinfectant solution directly into the
purifier chamber; 100-ppm of chlorine is suggested. With the disinfectant solution in the purifier chamber, turn the germicidal
ultraviolet purifier on. Open the "downstream" outlet until a chlorine or disinfectant solution odor is noticed. Close the outlet
and allow the disinfectant to remain in the plumbing for at least three (3) hours. Flush the plumbing with germicidal ultraviolet
purified water; allow the water to run for a minimum of 5 minutes before use (to ensure no chlorine or disinfectant solution
smell can be detected), this will allow the chlorine or disinfectant solution to be flushed through the pipes.
12.
For added protection, a suitable drain pan must be installed under the purifier. The drain pan must be
plumbed to an adequate, free flowing drain to prevent water damage in the event of a leak. There are numerous leak detection/
flood stop devices, available on the market today, designed to stop the flow of water, reducing the chance of water damage due
to leakage. For more details regarding leak prevention and/or limiting damages due to leaks, please contact

Recommended Options

1.
SENTRY
Safety Sensor (30-0168 or 30-0169): Indicators provide constant visual monitoring of normal operation. In the
TM
event of ballast or lamp failure the safety sensor indicates an alarm condition. The safety sensor is capable of operating an
optional audio alarm and/or solenoid valve.
2.
Promate
Audio Alarm (30-0173A or 35-2099): Activated by the Ultraviolet Monitor or Safety Sensor, alerts the user to
TM
any malfunction detected.
3.
Promate
Time Delay Mechanism (30-1369B or 30-0012B): Provides a 2-minute warm up period during which the
TM
germicidal ultraviolet lamp achieves its full germicidal output before the water is allowed to flow through the water purifier.
The time delay mechanism is used in conjunction with, and is electrically connected to the Solenoid Valve.
4. Promate
Solenoid Valve: Operated in conjunction with the Ultraviolet Monitor, Safety Sensor or Time Delay Mechanism,
TM
this valve prevents water flow through the water purifier when an abnormal condition is detected or in the event of
failure.
5.
SureFLO
Flow Control Valve: Limits water flow to the rated capacity of the purifier. The flow control valve is located in
TM
line prior to the water purifier, and should be protected from germicidal ultraviolet exposure by the use of a 90-degree elbow
fitting between the flow control valve and the water purifier. Unless otherwise specified PVC flow control valves are supplied.
Stainless Steel Flow Control Valves are available for certain models. All PVC and Stainless Steel flow control valves are male
NPT. Consult Factory for other flow control valves.
6.
Promate
Elapsed Time Indicator (30-1008A): A non-resettable display of the water purifier operating hours. Useful for
TM
scheduling and recording maintenance and lamp replacement.
7.
Promate
Safety Glasses (00-1299): Safety eyewear MUST be used as general-purpose safety protection and for additional
TM
shielding from germicidal ultraviolet rays.
8.
Promate
Face Shield (00-0126): Lightweight visor with adjustable headgear provides eye and face protection from
TM
germicidal ultraviolet rays.
NOTE: The recommended options above are available from Atlantic Ultraviolet Corporation
products. For the other devices that may be required for your application, please contact your local water treatment dealer,
plumber or plumbing supplier. If you have any questions, please contact Atlantic Ultraviolet Corporation
by phone or email: (631) 273-0500 – [email protected]
8
Step 2
Assembly onto Stud & Lock Washer over
Plug ballast into an approved Ground Fault Circuit Interrupt (GFCI) receptacle. Where a 2-prong or
Slide Ring Terminal Wire
Ring
Step 3
Install Nut on Stud against
Washer & Tighten with 7/16" Wrench
the factory.
or a distributor of their
®
®
power