Atlantic Ultraviolet G48HO 소유자 매뉴얼 - 페이지 15

{카테고리_이름} Atlantic Ultraviolet G48HO에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Atlantic Ultraviolet G48HO 20 페이지. Germicidal ultraviolet portable area sanitizer

Atlantic Ultraviolet G48HO 소유자 매뉴얼

TROUBLESHOOTING

Always disconnect power to the fixture before performing any service or maintenance.
IN ORDER TO PERFORM THIS TASK, WEAR PERSONAL PROTECTION EQUIPMENT; GLOVES,
LONG SLEEVE SHIRT WITH NO GAPS BETWEEN CUFFS AND GLOVES, AND AN ULTRAVIOLET
BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN.
IMPORTANT: This fixture is to be serviced ONLY by qualified and factory authorized personnel.
Problem
Possible Cause
Power disconnected
Sanidyne
Plus
®
not operating
Fuse not operating
STER-L-RAY
Germicidal lamp faulty
STER-L-RAY
STER-L-RAY
Lamp
®
lamp not properly seated
not operating
Loose Connection
Surelite
Sanidyne
Plus
Microprocessor
®
fails to shut off
assembly faulty

TECHNICAL SPECIFICATIONS

Model:
Volts:
Amps:
Hertz:
Maximum Treatment Time:
Weight:
Length: (Inches)
Dimensions:
Width: (Inches)
Height: (Inches)
Lamp Model:
Number of Lamps:
Lamp Data:
Power Consumption:  (Watts per Lamp)
Ultraviolet Output:  (Watts per Lamp)
Average Effective Life: (Hours)
Wattage is lamp watts only and does not include ballast loss.
 Ultraviolet output at 254nm at 100 hours and 80 °F (approximate).
All specifications, dimensional data, etc are approximate and subject to change without notice.
Table 1 – Troubleshooting
Corrective Action
Check connections.
Remove power connector to check and
replace fuse if necessary.
Swap suspect lamp, with lamp known to be good.
®
If suspect lamp does not operate, replace lamp.
Germicidal
®
Check lamp socket and re-install lamp if necessary.
Inspect for loose or disconnected wires.
Ballast not operating Disconnect the fixture from utility power; then replace ballast.
Wearing protective clothing and face shield, enter area, and
disconnect power to unit. Call factory for technical service.
Table 2 – Technical Specifications
40-5087C1
40-5087C2
120v
230v
10 A
5 A
50/60Hz
24 Hours
76 Lbs.
21-3/4"
20"
68-1/2"
05-0893
8
120W
35W
13,000
15