INSTALLATION
Installation using the supplied drawer fascia –
REHR6* WRH605I* WRH608I* WRH908I*
Standard ducted installation calls for a door extension of
130mm whether the client opts to use the supplied draw
fascia or a custom fascia of the same dimensions as that
supplied.
WRR614*A
Recirculating vent installation –
WRH608I* WRH908I (WRR614*A already fitted
with 70mm front panel)
Note: If the rangehood is to be vented using the
recirculating vent rather than standard ducting, the
supplied drawer fascia is not to be used and must be
replaced with a client specific custom fascia.
The custom drawer fascia must be a minimum of 70mm
deep as air expelled through the recirculating vent must
be deflected upwards.
Unscrew and
remove cover from
recirculating vent
Setting of circulation air doors
Exhaust
Recirculate
Ducted recirculating installation –
REHR6* WRH605I* WRH608I* WRH908I*
If ducted recirculating installation is used, carbon filters
are recommended.
All models optional carbon filter
An optional carbon filter will diminish cooking odours
in the recirculated air. Depending on the frequency of
use and the type of cooking, the expected life of carbon
filters from 1 to 6 months. Replacement is required. It
is recommended to use carbon filters for recirculating
installation.
Recirculating accessory
Optional carbon filter ARCFD for recirculating mode
only. Using carbon filters will reduce the airflow of the
rangehood.
AR125WV