TROUBLESHOOTING
!
WARNING:
Use personal protection equipment, such as gloves; long sleeves with no gaps between cuffs
and gloves, and ultraviolet resistant face shield, if troubleshooting AeroLogic
•
IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel.
Problem
Unit not operating.
Germicidal lamp not
operating.
TECHNICAL SPECIFICATIONS
Model No:
AERO-8
AERO-12
AERO-14
AERO-16
AERO-18
AERO-20
AERO-24
AERO-26
AERO-32
AERO-44
Ultraviolet output at 254nm at 100 hours and 80°F (approximate).
All specifications, dimensional data, etc. are approximate and subject to change without notice.
Always disconnect power to the unit before performing any service or maintenance.
Table 1 - Troubleshooting
Possible Cause
No electrical power...
Germicidal lamp not
properly seated...
Germicidal lamp faulty...
Ballast not functioning...
Table 2 - Technical Specifications
Current (A)
120v
220v
Lamp Model:
.12A
.10A
.16A
.16A
.21A
.17A
.22A
.19A
.23A
.20A
.25A
.23A
.27A
.26A
.30A
.29A
.32A
.36A
.50A
.46A
Corrective Action
Verify that the unit is connected to a live power source.
Confirm connection of lamp and lamp socket, make sure
connection is tight and lamp is making full contact with
lamp socket.
Replace lamp.
Replace ballast.
Lamp
Power
05-1119-R
10W
05-1366-R
14W
05-0218-R
17W
05-1370-R
21W
05-1523-R
22W
05-0117-R
25W
05-0097-R
29W
05-0219-R
32W
05-1382-R
39W
05-0197-R
50W
®
.
Ultraviolet
Length:
Output:
(into duct)
2.3W
7 5/32-in.
3.7W
10 7/64-in.
5.8W
14-in.
6.4W
15 31/32-in.
6.9W
17 1/32-in.
8.5W
20-in.
9.7W
23 7/32-in.
11.2W
26-in.
13.8W
32-in.
19.3W
44-in.
13