DRIFTON 206-DF 운영 매뉴얼 - 페이지 11
{카테고리_이름} DRIFTON 206-DF에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DRIFTON 206-DF 14 페이지. Drifton high precision dispenser for liquid
5. Piston Function
The pistons makes barrel filling easier. As you load the fluid in, air is
trapped in the bottom and throughout the fluid. Simply insert a piston and
gently press down on the fluid as far as possible. This action forces out
most of the air and results in consistent deposits.
A piston prevents fluids backflow. No air gap when using the piston
Using a piston has several advantages
1. Vacuum adjustment is much less sensitive.
2. The piston prevents fumes from the fluid being exhausted
into the work environment.
3. The piston prevents fluid backflow into the dispenser if the
barrel is inadvertently turned upside down.
4. Using the piston makes it easy and safe to change tips
without dripping.
5. Press the "Man" button.
6. With the barrel pointing downward over a container, unsnap
the safety clip. Then press the foot pedal to fill the tip.
Note: For best results, we strongly recommend that you use a piston
as part of your dispensing system.
6. Filling the Syringe Barrel
Caution: Do not completely fill syringe barrels. The optimum fill is a maximum
2/3 of the barrel capacity and 1/2 of the barrel capacity when using the Drifton
blue LV Barrier piston.
If the fluid you are dispensing is procurable, take the syringe barrel, twist on
a tip cap and pour your fluid in.
Insert a white piston and carefully press down until it contacts the fluid. The
syringe barrel is now ready for use.
If your fluid is thick or non-leveling, you can spoon it into the syringe barrel
with a spatula.
11