Atlas CP700 소유자 매뉴얼 - 페이지 9
{카테고리_이름} Atlas CP700에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Atlas CP700 16 페이지. Commercial dual channel power amplifiers
Atlas CP700에 대해서도 마찬가지입니다: 브로셔 (2 페이지), 소유자 매뉴얼 (16 페이지), 소유자 매뉴얼 (16 페이지), 사양 시트 (2 페이지), 브로셔 및 사양 (10 페이지), 소유자 매뉴얼 (16 페이지)
SPEAkEr OuTPuT WIrINg
CH-1
AUDIO TRANSFORMER
8, 4, and 2 Ohms
+
-
0
70
D I R . O U T P U T
Low Impedance Direct Coupled Output (Stereo)
For direct coupled operation into 2, 4, and 8 Ω loads, connect the loudspeaker leads to the barrier
strip connections labeled "Direct Output"; connect the hot lead to the "+" terminal and the
-
+
-
+
PROTECT
70V
25V
BRIDGE
common lead to the "-" terminal. The use of heavy gauge wiring is recommended to avoid voltage
MONO
- 100V +
CH-2
AUDIO TRANSFORMER
8, 4, and 2 Ohms
LIMIT
drops, which can occur as a result of wasted power in the cable. Contact Atlas Sound Tech Support
+
-
0
70
D I R . O U T P U T
(1-800-876-3333) for suggestions on cable capacities. Be sure you know the quantity of speakers
SIGNAL
and cable lengths before calling (Figure 5).
CH-1
CH-2
-
+
-
-
70V
25V
BRIDGE
MONO
- 100V +
POWER
CAUTION
RISK OF ELECTRIC SHOCK
AVIS RISQUE DE CHOC ELECTRIQUE
CP700
Commercial Power Amplifier
CH-1
8, 4, and 2 Ohms
AUDIO TRANSFORMER
+
-
0
70
D I R . O U T P U T
Low Impedance Direct Coupled Output (Parallel mono)
Observe the speaker connection information in the preceeding paragraph (Stereo Direct Coupled
-
+
-
+
70V
25V
Output). With the amplifier turned OFF, move the rear mounted selector switch to the "Parallel"
BRIDGE
MONO
- 100V +
CH-2
8, 4, and 2 Ohms
AUDIO TRANSFORMER
position and connect your mono input wiring to either the channel one or channel two inputs. Both
+
-
0
70
D I R . O U T P U T
channels will be driven from this mono signal (Figure 6).
-
+
-
-
70V
25V
BRIDGE
MONO
- 100V +
POWER
CAUTION
RISK OF ELECTRIC SHOCK
AVIS RISQUE DE CHOC ELECTRIQUE
AtlasSound.com
CP400 & CP700
Commercial Power Amplifier
CH-1
100
I S O L . O U T P U T
+
PROTECT
CH-2
LIMIT
100
I S O L . O U T P U T
SIGNAL
+
MADE IN CHINA
CAUTION
DO NOT OPEN
NE PAS OUVRIR
To direct coupled
loudspeakers
To direct coupled
loudspeakers
CH-1
100
I S O L . O U T P U T
+
CH-2
100
I S O L . O U T P U T
+
MADE IN CHINA
CAUTION
IN
DO NOT OPEN
AMPLIFIER INPUTS
NE PAS OUVRIR
CH-2
+
THRU
LEVEL
GND
CH-1
8, 4, and 2 Ohms
+
CP700
D I R . O U T P U T
Commercial
Power
Amplifier
Per Channel
Output Power
+
400 W / 4 Ohms
BRIDGE
350 W / 70.7 V
MONO
CH-2
8, 4, and 2 Ohms
+
D I R . O U T P U T
AC100V-50/60Hz
POWER
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
-
BRIDGE
MONO
POWER
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
White
Black
Shield
IN
CH-1
-
GND
-
+
THRU
LEVEL
STEREO
PARALLEL
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
(800) 876-3333 AtlasSound.com
Telephone: 800.876.3333 • Fax: 800.765.3435
– 9 –
Specifications are subject to change without notice.
Owner's Manual
IN
AMPLIFIER INPUTS
CH-2
+
CP700
THRU
Commercial Power Amplifier
LEVEL
GND
CH-1
AUDIO TRANSFORMER
-
0
70
100
I S O L . O U T P U T
-
+
-
+
70V
25V
- 100V +
CH-2
AUDIO TRANSFORMER
-
0
70
100
I S O L . O U T P U T
-
+
-
+
70V
25V
Figure 5
IN
- 100V +
AMPLIFIER INPUTS
MADE IN CHINA
CAUTION
CH-2
RISK OF ELECTRIC SHOCK
DO NOT OPEN
+
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
THRU
LEVEL
GND
Optional Jumpers
See Note on Page 6
IN
CH-1
-
GND
-
+
THRU
POWER
LEVEL
STEREO
PARALLEL
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
Switch set
to "Stereo"
IN
CH-1
-
GND
-
+
THRU
LEVEL
STEREO
PARALLEL
BRIDGE
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
Switch set
to "Parallel"
Figure 6