Installation work, connection, disconnection, electrical wiring, mechanical
maintenance and service must be done by qualified people observing these
instructions and in accordance with all applicable norms and standards.
If the unit is operated with additional controller, please consider its specific
instructions.
The electrical connection is made with a shucko connector. It is not necessary
to open the service panel to connect the equipment. The equipment fixings are
external (in the standard model, located at the top or rear of the purifier). To
make a repair or replacement it is necessary to open the service side panel.
(see repairs section).
MIN. Recommended minimum distance.
Be careful, the more free space you give to the equipment, the better air quality you can get. For this, it is
necessary to respect the following installation measures:
Suction plane: Minimum free area of 200mm (recommended to clear the maximum space to facilitate the
suction of particles).
Discharge plane: Minimum free area of 500mm (it is recommended to clear as much space as possible to
make it easier for the OH to spread throughout the room (Dimension C).
Upper plane: Minimum separation with the ceiling of 10 mm (Dimension A).
Lower plane: Minimum free area of 300mm from cyclonic tank (cartridge replacement and emptying of the
cyclonic tank) (Dimension D).
Maintenance plane 500mm free area, recommended 1 metre.
Opposite plane to maintenance 10mm.
4

INSTALLATION

Instructions manual - Purificator Cyclohic