Airtecnics K7 HEPA 설치 매뉴얼, 운영 및 유지보수 - 페이지 11
{카테고리_이름} Airtecnics K7 HEPA에 대한 설치 매뉴얼, 운영 및 유지보수을 온라인으로 검색하거나 PDF를 다운로드하세요. Airtecnics K7 HEPA 16 페이지.
The service panel covers the inside of the unit� Through it you can access the fans and the connection
box��
0- Service panel
Before replacing the fan, it is necessary to notify that it is working, disconnect the current, make sure that
there is no voltage and the turbine does not rotate�
Open the service panel as indicated in the previous section�
1- Disconnect the fan power ca-
bles inside the connection box
The new fan is installed following the above procedure in reverse order, making sure that the connection in
the IP box is correct (follow instructions on page 4)�
Service panel opening
1- Remove the screws
Fan replacement
2- Remove the screws
Instruction manual - Purifier
2- Gently remove the
service panel down
3- Remove fan
K7 770 HEPA
11