Assembly
Note
Please additionally secure all screwed connections in metal with screw locking device.
Mounting the
1 Fit the centering ledges (3) to the field (2)
field
(take care of the right position, see
illustration).
2 Insert the field (2) into the field housing
(1) (lightly hit the field housing with a
plastic hammer).
3 Insert the silicone buffer (4) into the air
supply ring (5).
4 Insert the air deflector plate (5) (take care
of the right position, see illustration).
Assembling and
1 Push the bearing (6), the washer (4) and
mounting the
the seal ring (5) (take care of the right
armature
position: the small boring faces the
toothed gear) onto the armature shaft and
press on the toothed gear (3) as fas as
will go.
2 Insert the complete armature (7) into the
field.
3 Push the silicone buffer (2) onto the field
housing.
4 Fix the angle (1) in the field housing.
5 Push the seal ring (9) onto the field
housing.
Mounting the
1 Insert the motor (4) into the motor
motor
housing (2) (take care of the right
position: the lug (3) must fit into the relief
of the motor housing).
2 Fasten the motor with screws (1) and (5)
(2,5 Nm).