6.2 Repair procedures
Repairs should be performed by a qualified technician!
Disconnect the power supply before performing any service or maintenance on the unit.
Failure to do so may result in serious injury or death.
GLACIER (CS5-16-VD-TB) Fan Motor Replacement
1. Remove cooling pads (see section 5.1 for pad removal instructions)
2. Remove the black motor wiring plate and disconnect motor wires. (Mark each wire with a
marker or marker tape to allow for easy matching when installing new motor.
3. Remove the (4) nuts and bolts that mount the motor, fan, and support braces (complete
fan assembly).
4. Replace new fan assembly.
5. Secure with 4 nuts and bolts.
6. Replace any wire ties that were removed when taking out the old fan assembly.
7. Replace the black motor wiring plate.
8. Reinstall pads and connect power
GLACIER (CS5-16-VD-TB) Pump Replacement
1. Loosen PVC Union
2. Remove pump and PVC pipe
3. Unplug the cord from the top of the pump by removing 2 screws
4. Unscrew PVC pipe from the pump
5. Reverse steps 1-4 to reinstall the new pump
6. Reinstall cooling pads and guards, reconnect power, and test pump
6.3 Technical support
Technical support and service are available directly from your distributor or
COOL-SPACE
Visit:
www.cool-space.com
ELECTRICAL SHOCK HAZARD
®
Technical Support Line at 1-800-557-5716