Advanced Radio Air Safe 사용자 설명서 - 페이지 7

{카테고리_이름} Advanced Radio Air Safe에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Advanced Radio Air Safe 12 페이지. Failsafe gear sequencer

Sequencer Screen

SEQUENCE DOWN/UP This feature allows you to man-
ually operate the sequencer without the need for the
TX to be switched on.
To use this feature move the cursor to the SEQUENCE
DOWN item.
THEN...
Joystick → RIGHT Arrow — Starts a Sequence to the up position.
Joystick ← LEFT Arrow — Starts a sequence to the down position.
Joystick PRESS — Stops the sequence at the current sequence step.
Hint: The current sequencer position will be shown at the top right of the screen
Please Note: From the factory the sequencer is programmed with all outputs in the down
position for all sequence steps so you will not see any movement on the output channels
until the sequencer is programmed. A FAIL SAFE event will also over-ride the manual se-
quencing functionality.
Sequencer Outputs 1-6
Selecting this menu item will take you to the output
setup screen.
Highlight and select any output to set up:
Air valve end points, or reverse air valve function.
Servo end points, or reverse servo function.
There is also a speed setting to slow servo travel.
Continued over page...
Screens and Usage
RETURN
SEQUENCE DOWN
SEQUENCER SETUP
SEQ OUTPUT 1—6
RETURN
SEQUENCE DOWN
SEQUENCER SETUP
SEQ OUTPUTS 1 - 6
RETURN
SEQ OUTPUT 1
SEQ OUTPUT 2
SEQ OUTPUT 3
SEQ OUTPUT 4
SEQ OUTPUT 5
SEQ OUTPUT 6
DOWN-1
DOWN-1
7