5.0 Installation
5.2.2 Unbalanced operation (cont.)
For the quick connect terminal block, pin 3 carries the + (hot, non-inverting) side of the
signal, and pin 1 is ground. Short pin 2 to pin 1 in order to reference the input differential
amplifier for the correct gain (see Figure 30).
Note: The gain remains the same whether the input is balanced or unbalanced. However,
if you make an unbalanced connection with a balanced source, there will be a -6dB gain
loss.
Use Class 2 Wiring
For bridged operation.
Consult user manual.
WARNING
RISK OF HAZARDOUS
ENERGY! MAKE PROPER
SPEAKER CONNECTIONS.
SEE OPERATING
MANUAL BEFORE USING.
AVERTISSEMENT
ENERGIE ELECTRIQUE
DANGEREU SE. VOIR
LANOTICE
DE FONCTIONNEMENT.
2
J20018292
+
RECV
2
1
3
PN# 1234567
26
INPUT IMPEDANCE 25K OHMS EACH LEG TO GROUND (TOTAL 50K OHMS BALANCED)
SEND
RECEIVE
PUSH
INPUT CH 2
SEQUENCE
1
EQUALIZATION
ON
CH1
3
CH2
CH2
EQ. OUT
CH1
GND(shield)
AM264080_00_V.pdf • June 21, 2002
PUSH
INPUT CH 1
2
1
3
GND(shield)
Figure 30
Quick connect terminal block
unbalanced input connection