Bose FreeSpace E4 Series II 소유자 매뉴얼 - 페이지 8
{카테고리_이름} Bose FreeSpace E4 Series II에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Bose FreeSpace E4 Series II 18 페이지. Business music system
Bose FreeSpace E4 Series II에 대해서도 마찬가지입니다: 빠른 시작 매뉴얼 (4 페이지), 소유자 매뉴얼 (16 페이지), 소유자 매뉴얼 (15 페이지), 소유자 매뉴얼 (33 페이지)
8.3 FreeSpace
E4 system Error Log
®
The FreeSpace E4 system Error Log is displayed when the
Installer™ software is in the Service Hardware mode.
8.3.1 Contents of the Error Log
The Error Log displays E4 system hardware version numbers and
records all alarms and their causes as shown in the following
example.
Hardware
Bose
version
-------------------------------------------------
numbers
Microcontroller: v1.0.0.64
DSP: v1.0.71.0
Peripheral: v1.0.0.10
Lower Amplifier: v1.0.0.14
Upper Amplifier: v1.0.0.14
Type of alarm
-------------------------------------------------
power-on self-test alarm (ok)
2002/12/31 23:59
Name of test
host controller test:
[OK]
Test results
host controller flash test:
[OK]
peripheral controller test:
DSP test: 1
upper amplifier test:
[OK]
8.3.2 Hardware configuration
The E4 system hardware version numbers appear at the top of
the Error Log listing. These are the version numbers of the soft-
ware installed in the E4 hardware at the time of manufacture.
These version numbers do not pertain to the FreeSpace
Installer™ software installed on your PC.
8.3.3 Power-on self-test results
The power-on-self test (POST) results are only displayed when an
error has occurred. The POST test checks the basic operation of
the E4 hardware to determine if it is capable of properly perform-
ing audio processing and amplification. During the POST test, six
major components of the hardware are tested.
8.0 E4 System Troubleshooting
®
FreeSpace E4 Series II Error Log
• Host controller – The host controller monitors and controls the
operation of the E4 hardware. A host controller failure will
cause the message, "Power-on self-test incomplete" to appear
in the host controller test section. The failure type for a host
controller is an SRAM address failure. If this occurs, contact
Bose Customer Service. See "Customer support" on page 70.
• Flash memory test – The flash memory contains the configu-
ration, design file, and system event schedule. A flash failure
will cause the message, "Power-on sel-test incomplete" to
appear in the host controller flash test section. If this occurs,
contact Bose Customer Service. See "Customer support" on
page 70.
• Peripheral controller – The peripheral controller monitors con-
tact closures, front panel connections and user interface con-
nections for incoming event messages. Any failures in these
areas will cause the message, "Power-on self-test incomplete"
to appear in the peripheral controller flash test section. If a 12C,
or code failure occurs, contact Bose Customer Service. See
"Customer support" on page 70. If a user interface failure
occurs, check the user interface wiring for shorts.
• DSP test – The DSP performs all signal processing and routing
functions. If a DSP error occurs, contact Bose Customer Ser-
vice. See "Customer support" on page 70.
• Upper and lower amplifier test – The upper and lower ampli-
fier test determines if the amplifiers are operating properly. An
amplifier failure will cause the message, "Power-on self-test
incomplete" to appear in the upper or lower amplifier section of
the POST test results. If a 12C, or code failure occurs, contact
Bose Customer Service. See "Customer support" on page 70.
Additional details on the exact cause of an amplifier failure can
be found in the amplifier section of the Error Log.
• Front panel board test – The front panel board test deter-
mines if the USB port is working properly. A USB failure will
cause the message, "Power-on self-test incomplete" to appear
in this section of the POST results. If a USB failure occurs, con-
tact Bose Customer Service. See "Customer support" on
page 70.
Programmer's Note: The USB port is not currently
used for communication with the E4. If a USB failure
occurs, the E4 will still function normally for audio pro-
cessing and amplification.
65 of 80