Remote control connections
Remote volume and source selection control
The amplifier is designed to work with the Bose
or the volume control user interface accessory (PC 041966). The REMOTE connector on the rear panel of the amplifier is
labeled to match the connector on the user interface. Use the included 4-pin Euroblock. See the appropriate Bose volume
control user interface install guide for more details.
Bose
1
PWR
volume
control
with
2
VOL
A/B
switch
3
COM
4
A/B
IZA 2120-LZ/HZ
IZA 2120-HZ remote configuration examples
Configuration example 1
REMOTE 1 can be a Bose volume control with A/B switch user interface accessory (PC 041967). REMOTE 1 will
control the level and source selection of both outputs simultaneously. This configuration requires setting the REMOTE
1 CONTROL DIP switch to ZONE 1+2 and the A/B SELECT DIP switch to REMOTE. If only one remote is being used,
this switch must be set to ZONE 1+2. If this switch is set to ZONE 1, the REMOTE input will not operate, and front panel
controls will be active.
Bose
volume
1
PWR
control
with
2
VOL
A/B
switch
3
COM
4
A/B
IZA 2120-HZ
volume control with A/B switch user interface accessory (PC 041967),
®
REMOTE
DIP switch settings
REMOTE 1
Bose
1
PWR
volume
control
2
VOL
IZA 2120-LZ/HZ
Making Connections
REMOTE
English - 29