Absen KL1.5 사용자 설명서 - 페이지 16
{카테고리_이름} Absen KL1.5에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Absen KL1.5 20 페이지.
4.2 Power cable wiring
KL series cabinets adopts 3×1.5mm² power line to connect distribution box or socket with the
power connector in the cabinet.
Maximum
power
Type
consumption
KL1.2
582W/m2
KL1.5
555W/m2
KL1.8
540W/m2
KL2
480W/m2
KL2.5
540W/m2
KL3
540W/m2
KL3.9
360W/m2
4.3 Network cable wiring
For signal line wiring, please calculate the resolution ratio according to the pixel points of each
cabinet. Note that the maximum belt load of a single net port does not exceed 65W pixel points,
and the overall belt load does not exceed the belt load limit of the sending box.
16
Maximum recommended load for single main
power line
110V
4
5
5
6
5
5
8
KL Series Product
220V
9
10
10
12
10
10
16
User Manual