Droplet Genteel 사용 지침
{카테고리_이름} Droplet Genteel에 대한 사용 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Droplet Genteel 2 페이지. Lancing device
lancing device
Your Droplet Genteel lancing device comes with:
Droplet Genteel lancing device
6 Contact Tips
If any of these items are missing, appear damaged,
or you have any concerns, please contact Customer
Service at [email protected] or call 1-877-660-1900.
Droplet Genteel lancing device parts
Contact Tip
Nozzle
Lancet
This is NOT a Droplet Genteel part
Shuttle
Front End
Activation Button
Hole in Activation Button
Push Cap
I N STRUCTION S
FOR US E
Warnings
The Droplet Genteel lancing device is designed for single
user only. Never share the lancing device or lancets. Using
the Droplet Genteel lancing device, any of its parts, or any
lancing device on multiple individuals may increase the risk
of inadvertent transmission of bloodborne pathogens.
We recommend that you wash your hands with soap and
water before and after handling the Droplet Genteel lancing
device to prevent the transfer of bloodborne viruses or
infectious agents.
Always use a new lancet for each test. Never reuse lancets.
Precaution
Always follow the instructions provided with your meter
for blood glucose testing.
Do not store the Droplet Genteel lancing device in high
temperatures above 150°F/66°C, typical of the dashboard
of a car on a hot, sunny day with the windows rolled up.
Setting up Droplet Genteel for use
1
Droplet Genteel lancing device with
a Contact Tip on the Nozzle
See Choosing the Contact Tip and
!
Installing the Contact Tip on the Nozzle
2
A sterile lancet
See How to know if a lancet
!
will fit with Droplet Genteel
3
Alcohol swab and/or tissue
to clean test site
The Droplet
Genteel
lancing device is used with disposable sterile
®
®
lancets to draw capillary blood from the fingertip or alternate sites
for blood glucose testing or other utilizing small amounts of blood.
The Droplet Genteel lancing device is for single patient use only.
Please read these instructions from beginning to end before using for
the first time. Retain this manual for future reference. In addition to reading
the instructions, watch the quick start video at www.mydropletgenteel.tips
Choosing the Contact Tip
Undercut
Body contact side
1
2
3
4
5
Blue
Yellow
Green
Clear
Orange
Shallowest
The Droplet Genteel lancing device comes with 6 Contact Tips,
different in color and thickness. They range from #1/thickest (Blue)
through #6/Thinnest (Violet). These thickness differences allow you to
adjust the depth of penetration of the lancet. To minimize discomfort,
use the shallowest depth (thickest, lowest number) Contact Tip that
still produces the right amount of blood.
Droplet Genteel comes factory-installed with the Blue #1 Contact Tip.
This is the thickest Contact Tip and allows for the shallowest depth
penetration. We recommend that you try the Blue factory-installed
Contact Tip the first time you use Droplet Genteel. Changing the
Contact Tip to a higher number will allow a deeper puncture depth.
How to know if a lancet will fit with Droplet Genteel
Shape
Is the base of the lancet square?
Droplet Genteel was designed to
work with most square shaft lancets.
Fit
Does the lancet fit and stay in the
shuttle, even if you shake the device?
Size
Remove the Contact Tip from the Nozzle.
Hold Nozzle with the small side up. Drop
the lancet down through the Nozzle. Does
the lancet pass all the way through?
If your lancet does not pass these three tests, it will not work with
Droplet Genteel. However, passing these tests only means it will fit
into Droplet Genteel's shuttle, but does not guarantee its overall
quality or that the needle size is uniform.
The Droplet Genteel lancing device works with Droplet Personal
Lancets. It is recommended that you use Droplet 30G Personal
Lancets with the Droplet Genteel lancing device.
6
Violet
Deepest
.25 in
.64 cm