Once the pumps have been inserted in the drums and after connecting them to the pipes complete with distribution guns,
they can be started up following the procedures described below.
This procedure requires simple operations which, in designing the machine and, more precisely, the grease and oil transport
line, took into consideration the work execution methods that the operators carry out in the various phases of lubrication
and greasing, oil top-off, etc.
Opening the compressed air valve, the pump starts up and the entire oil/grease output pipe pressurises until
reaching the set adjustment value. Once this value has been reached, the pump stops
Acting on the oil/grease output gun, the product is delivered and the pressure in the circuit consequently decreases.
The pump starts up until the set pressure value is restored.
8. PROBLEMS AND SOLUTIONS
FAULT
The pneumatic motor
does not work.
The pneumatic motor
woks but does not pump
the product
The pump does not
maintain pressure.
TROUBLESHOOTING TABLE
CAUSE
• Problems with the air supply
line.
• Pumping rod locked
• Internal breakage
• No lubricant in the drum
• The suction is clogged by
impurities
• Wear of valves or gaskets.
• Wear of valves or gaskets.
SOLUTION
• Check the air supply connections.
Check the air handling unit.
• Disconnect the rod and ensure that
it slides freely, otherwise
disassemble and clean it.
• Disconnect the rod and ensure that
the motor works, otherwise
disassemble and clean it and replace
any damaged parts.
• Fill or replace the drum
• Disassemble the rod and clean it
internally.
• Disassemble the rod, clean it
internally and replace the worn
components.
• Disassemble the rod, clean it
internally and replace the worn
components.
6