Control
cylinder
Single acting
inlet/outlet G ¼

6. UNPACKING AND INSTALLATION

6.1. UNPACKING
Once you have identified the suitable place for installation, open the package and remove the pump, and check that it has not
suffered any damages during transport and storage. The packing material does not require special disposal precautions as it is
in no way dangerous or pollutant. For disposal, refer to local regulations.
6.2. INSTALLATION
The unit has a bracket with 4 holes Ø 8.5 mm (0.33 in) for securing the pump to the floor.
Leave at least 100 mm (3.94 in) as a perimeter distance with respect to other equipment or barriers to prevent access to the
pump.
Assemble the pump at "labourer height" in order to prevent abnormal posture or possible impact.
Do not install the pump submerged in liquids and/or in aggressive environments.
Do not install the pump in environments where there are explosive or flammable mixtures.
Ensure that the pipes and wires have been properly fastened and protected from any possible impact.
Verify that the grease used is fit for operating temperatures, especially at temperatures below 0° C. If in doubt, contact our Sales
Technical Office for the correct choice of lubricant.
6.3. HYDRAULIC CONNECTIONS
Dual acting
with solenoid
valve 4/2
ATTENTION: The pipeline must reach the point of lubrication along the shortest route possible.
SINGLE ACTING VERSION WITHOUT RESERVOIR
Lubricant inlet
G ½
Single acting
with solenoid
valve 4/2
Output
lubricant
Fixing
bracket
Output
lubricant
Flow rate adjustment
Air supply bleed
screw
Lubricant outlet Rp ¼
Single acting
with solenoid
valve 3/2
Output
lubricant
4