7. PUMP OPERATIONS
After installing the pump, adjust driving air pressure.
7.1 Prior to pump start-up
Verify the unit is undamaged.
Check that pneumatic and electric connections (IEC 64/8, IEC 364) have been carefully carried out.
Refill the reservoir with compatible lubricant.
Verify operating temperature [MIN temperature: -5°C (+23°F)].
7.2 Pump start-up
Verify piping are air-bubble-free.
Verify that lubrication is correctly carried out.
8. TROUBLESHOOTING
WARNING: The unit can only be opened and repaired by authorized Dropsa personnel.
The following diagnostic table indicates the main anomalies which may be encountered, the probable causes and possible
solutions. If you cannot solve the problem, do not attempt to disassemble parts of the machine but contact the Eng.
Dept. of DROPSA S.p.A.
ANOMALY
Lubricant is not
delivered by pump at all
or in the required
quantity
Lubricant is not
delivered by pump at
the required pressure
9. MAINTENANCE PROCEDURE
Pneumatic-driven Pump, Series 3414.... require only minimal maintenance.
To facilitate maintenance, it is suggested to install the pump in an easily accessible location (see paragraph 6.2).
Machine does not require any special tool for checking or maintenance tasks. However, it is recommended the use only
of appropriate and in good conditions tooling, protective devices (gloves) and clothing to avoid hazards to equipment
or persons.
CAUTION!
Prior to any maintenance and cleaning task, discharge pressure from pump and from the respective
connected piping.
9.1 How to disassemble the pump
Empty the reservoir;
-
Disconnect the piping;
-
Unscrew the fixing screws;
-
Remove the reservoir;
-
Remove the pump and the provided filters;
-
Unscrew the pneumaticcylinder from pump;
-
Remove all the other components.
-
PROBABLE CAUSE
Lubricant is below the MIN. level
Solenoid valve does not discharge
Loosened pipe fitting
Incorrect regulation of driving air
SOLUTION
Refill the reservoir with impurity-free lubricant.
Do not exceed the MAX level indicator
Verify that solenoid valve is 3-way.
also, that air is properly discharged from pump
chamber.
Carefully retighten pipe fitting. Be sure there are
no lubricant leakages.
Regulate driving air according to the technical
characteristics (see ch. 4)
Verify,
4