DROPSA 37012 사용자 및 유지보수 매뉴얼 - 페이지 9

{카테고리_이름} DROPSA 37012에 대한 사용자 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DROPSA 37012 16 페이지. Motor driven gear pumps

DROPSA 37012 사용자 및 유지보수 매뉴얼
Gear pumps and electro-gear pumps, (pumps with horizontal fastening)
Max Pressure = 30 bar for continuous working – Max Pressure =60 bar for intermittent working.
Fluid working temperature = 20÷100 ºC with low and medium oil viscosity.
Note: For pumps either with clockwise rotation or bi-rotational with suction on left side, connect suction line to threaded port 1
and delivery line to threaded port 2 ;
For pumps either with counter - clockwise rotation or bi-rotational with suction on right side connect suction line to threaded
port 2 and delivery line to threaded port 1;
WITHOUT BY PASS
Rotation #
Weight
Liters
kg
Left
Right
2
37060
0,9
3,5
37036
37021
10
37024
1,9
19
37040
3,2
32
37030
5
WITH BY PASS
Rotation #
Weight
Liters
kg
Left
Right
2
37061
1
3,5
37111
37022
5,5
37063
2,1
10
37039
37025
REVERSIBLE
Sunction
Weight
Liters
kg
Left
Right
2
37070
0,9
3,5
37023
5,5
37071
1,9
10
37026
* Please ask to nearest Dropsa for availability
Dimensions and features may change without notice
Gas
D
E
F
G
H
1/4
40
8,7
10
25
3/8
54
12,3
12
30
1/2
65
15,2
14
32
3/4
77,5
18,9
16
34
Gas
D
E
F
G
H
J
1/4
40
8,7
10
25
3
3/8
54
12,3
12
30
4
Gas
D
E
F
G
H
J
1/4
40
8,7
10
25
3
3/8
54
12,3
12
30
4
Dimensions (mm)
J
K
L
M
N
O
3
11,2
44,5
45,5
25
48
4
13,5
57
61
35
60
5
16
67
73
44
74
5
18,8
72
79
50
84
Dimensions (mm)
K
L
M
N
O
11,2
44,5
...
25
48
13,5
57
...
35
60
Dimensions (mm)
K
L
M
N
O
11,2
44,5
...
25
48
13,5
57
...
35
60
P
Q
R
S
T
65
8
60
60
14,5
82
10
80
80
18,5
96
10
90
98
25
110
10,5
108
116
25
# Looking at the pump from shaft side
P
Q
R
S
T
65
8
60
60
14,5
45,5
82
10
80
80
18,5
# Looking at the pump from shaft side
P
Q
R
S
T
65
8
60
60
14,5
82
10
80
80
18,5
120,5
U
V
W
Z
...
...
6
...
...
...
9,5
...
...
...
9,5
...
...
...
11,5
...
U
V
W
Z
58
6
...
61
78
9,5
...
U
V
W
Z
90
...
6
49,5
...
9,5
69
9