DROPSA 989002 사용자 및 유지보수 매뉴얼 - 페이지 3
{카테고리_이름} DROPSA 989002에 대한 사용자 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DROPSA 989002 14 페이지.
5. MACHINE COMPONENTS
5.1 Minimum level indicator
Electro-mechanical type
Normally closed at minimum level. Maximum commutable power ISA; maximum commutable voltage 220/240 VAC.
5.2 Pressure gauge (Accessory)
Part No.
3292099
5.3 BY-PASS VALVE (Accessory
Part No.
888036
It is possible to adjust working pressure by means of a by pass valve installed on delivery line.
The use of the by pass valve it's recommended to control the pump operating and to avoid over pressure in the circuit.
5.4 Filling filter
This removable cartridge filter is recommended to ensure the filling of lubricant which is free from foreign bodies and
to avoid the formation of air bubbles. Type of lubricant: Grease NLGI 2
PRESSURE RANGE
0 ÷ 400 Bar (0 ÷ 40 Mpa)
)
PRESSURE RANGE
0 ÷ 250 bar (0 ÷ 3675 psi).
3