Daikin BRC7FB532F 운영 매뉴얼 - 페이지 11
{카테고리_이름} Daikin BRC7FB532F에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Daikin BRC7FB532F 12 페이지. Wireless remote controller kit
![Daikin BRC7FB532F 운영 매뉴얼](/uploads/products/server2/1512569/1512569.jpg)
Symptom 2: The unit stops once in a while
Example
The remote controller
indicates "U4" and "U5",
the unit stops. Within
several minutes the unit
restarts.
Symptom 3: No changeover is available between
heating and cooling modes
Example
The indoor unit makes a
"PEEE" receiving sound.
Symptom 4: Air flow rate cannot be obtained as set
Example
Even if the air flow rate
adjusting button is
pressed, the air flow rate
does not change.
Symptom 5: Air discharge direction is not as set
Example
The remote controller
indication and the air
discharge direction is not
the same.
Air discharge direction
swing is impossible.
Symptom 6: Only a part of indication shows
Example
Even if the unit is
operated, only the
operation indication
shows, or even if the
indication shows, soon
after, the indication other
than that for operation
disappears.
BRC7FA532F(B) + BRC7FB532F(B)
Wireless remote controller kit
Reason
Due to electrical noise
other than that from the
air conditioner, the
communication between
the units is cut off and the
unit stops.
When the noise is gone,
the unit automatically
restarts.
Reason
When operation
changeover is under
control, the control is set
to the mode that cannot
be carried out.
Reason
When the room
temperature reaches the
indoor unit set
temperature, the outdoor
unit stops and the air flow
rate of indoor unit drops
to the minimum.
This is to avoid the cold
air from getting in contact
with the people in the
room.
Reason
Because it is controlled
by microcomputer. Refer
to "AIR FLOW
DIRECTION ADJUST" on
page 5.
Reason
The corresponding indoor
unit is that for multi-
system and the remote
controller is set to the
multi-system.
4P563995-1 2019.01
Symptom 7: No indication shows or all indication
show
Example
When the remote
controller button is
pressed.
Symptom 8: Insufficient cooling
Example
It is in program dry
operation.
Disposal requirements
Batteries supplied with the remote controller
are marked with this symbol.
This means that the batteries shall not be
mixed with unsorted household waste.
If a chemical symbol is printed beneath the symbol, this
chemical symbol means that the battery contains a
heavy metal above a certain concentration. Possible
chemical symbols are:
■ Pb: lead (>0.004%)
Waste batteries must be treated at a specialized
treatment facility for re-use.
By ensuring waste batteries are disposed of correctly,
you will help to prevent potential negative consequences
for the environment and human health.
Reason
The battery is dead.
Reason
The program dry
operation is an operation
mode trying to keep the
room temperature
constant as much as
possible. Refer to
"Cooling, Heating,
Automatic, Fan and
Program dry operation"
on page 4.
Operation manual