Parameter
Number of Pump
Cycles
Pump On
Pump Off
Number of Micro-
Pumps
Min air pressure
Max Air Pressure
Standby Impulses
DISPENSE MODE PARAMETERS
Display
Number of pump cycles performed
when lubricating/dispensing. From 1 to
9999
The amount of time the pump remains
ON when dispensing.
Range: 0.1s to 9.9s
The amount of time the pump remains
OFF when dispensing
Range : 0.3 to 9.9 s.
Number of Micropumps installed on
the system with Flow Sensing. Setting
this to 0 will disable flow sensing on all
micropumps. If you set less than the
number of micropumps installed than
the nearest ones will be monitored,
while the furthest will remain
unmonitored. EG. Setting 5 of a 6
pump system will result in the last
pump not being monitored..
Minimum Air Pressure monitoring
during cycle. Setting 0.0 disables
minimum air pressure monitoring.
Range 0.0-7.0 bar.
Maximum Air Pressure parameter
during cycle. Setting 0.0 disables
monitoring.Range 0.0-7.0 bar
Number of impulses required to
initiate the Lubrication/Dispensing
Cycle.
Settable from 0001 to 9999.
Description
Operation
Set the value using the
and
keys
Set the value using the
and
keys
Set the value using the
and
keys
Set the value using the
and
keys
Set the value using the
and
keys
Set the value using the
and
keys
Set the value using the
and
keys
Default
1
1
1
Min. 0
Max. 6
0.0
2.5
3
8