ANLIDAR MyTorq MY8-EP0205P 운영 및 유지보수 매뉴얼 - 페이지 6

{카테고리_이름} ANLIDAR MyTorq MY8-EP0205P에 대한 운영 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ANLIDAR MyTorq MY8-EP0205P 13 페이지. Dc-type automatic non-carbon-brush with counter series

1) Whenever changing a bit, make certain the Forward / Reverse Switch is in "OFF "position and tool is unplugged.
2) Do not allow chemicals such as acetone, benzene, thinner, trichloroethylene ketone, or other similar chemicals to come in contact
with the screwdriver housing as damage will result.
3) Do not drop or abuse the screwdriver.
4) Do not adjust the torque setting higher than 8 on the torque scale.
5) Operation frequency: The original setting of the frequency is 1 sec on / 3 sec off. The number of screws fastened is
about 15 pcs. Over frequently using makes the motor overheated and damage to screwdriver.
Enough heat-dissipation is good for screwdriver.
Slow speed Duty Cycle Conversion (for reference)
Based on 1000 rpm, 1 second ON/3 seconds OFF. For example, the duty cycle for 350rpm,1000-350=650,
650/1000%=65%
ON= 1*1.65= 1.65,OFF =3*1.65 =4.95 (rounded value) =2 seconds ON / 5 seconds OFF
This tool is intended for a duty cycle of 2.0 sec on, 5.0 sec off.
Slow speed (rpm)
operation frequency
900
1.0 ON 3.0 OFF
850
1.0 ON 3.0 OFF
800
1.0 ON 3.0 OFF
750
1.0 ON 3.0 OFF
700
1.0 ON 3.0 OFF
650
1.0 ON 3.0 OFF
6) Do not use this screwdriver for tightening wood screws. This is "Metal Assembly Screwdriver"
7) Do not operate the Forward / Reverse Switch the motor is running.
8) Whenever a tool is not being used, move the Forward / Reverse Switch to "OFF" position and unplug the screwdriver.
9) Don't touch Forward / Reverse Switch during operating for keeping system from wrong judgement.
10) Use cable for the external counter and I/O box is shield cable for avoidance of electrical interference
Use shield cable.
When replacing the control PCB or clutch assembly of electric screwdriver, the screwdriver is
11)
required to do calibration with MY-TR.
● Do not drop or abuse the tool.
● Whenever a tool is not being used, position the Power Switch to the "OFF" position and unplug the power cord.
Attaching / detaching bit and bit type
Push up the holder clamp by finger tip, and it will be unlocked. Thus, the bit can be freely attached and detached (single finger
notion type) select such a bit whose shank is equal to the size shown below.
 Insert the power plug into a receptacle and set the changeover switch to "F" position.
 Apply the bit to the screw head and press the lever or push main body to, then the switch will be turned ON to start
the motor running.
 When the screw is tightened and reach the torque that you had set, the tool will be stopped automatically.
 To reset the tool by releasing the lever to the original position or releasing the bit from the screw head.
 To return the screw, set the changeover switch to "R" position.
Operations Cautions
Slow speed (rpm)
operation frequency
600
1.0 ON 3.0 OFF
550
2.0 ON 5.0 OFF
500
2.0 ON 5.0 OFF
450
2.0 ON 5.0 OFF
400
2.0 ON 5.0 OFF
350
2.0 ON 5.0 OFF
CAUTION

Description of Operation

5
Slow speed (rpm)
operation frequency
300
2.0 ON 5.0 OFF
250
2.0 ON 5.0 OFF
200
2.0 ON 5.0 OFF
150
2.0 ON 5.0 OFF
100
2.0 ON 5.0 OFF