Daikin ADS 설치 및 유지 관리 매뉴얼 - 페이지 3
{카테고리_이름} Daikin ADS에 대한 설치 및 유지 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Daikin ADS 14 페이지. Chiller unit controller/communication module
This manual contains information regarding the network
integration system used with MicroTech III unit controllers on
Daikin Applied chillers. It describes how to install or replace a
L
W
communication module on a MicroTech III chiller unit
on
orks
controller. It also explains how to set network parameters and
establish communication between the chiller and L
network.
Revision History
IM 968
October 2009
IM 968-1
March 2012
IM 968-2
January 2017
IM 968-3
March 2017
IM 968-4
January 2018
Reference Documents
Company
Number
Title
Pathfinder
Cooled Chiller Installation,
Daikin Applied
IOM 1202
Operation, and Maintenance
Manual
Pathfinder Model AWV Air
Cooled Chiller Installation,
Daikin Applied
IOM 1242
Operation, and Maintenance
Manual
Trailblazer
Cooled Chiller Installation,
Daikin Applied
IOM 1206
Operation and Maintenance
Manual
Trailblazer Model AMZ Air
Cooled Chiller Installation,
Daikin Applied
IOM 1243
Operation, and Maintenance
Manual
Magnitude Model WME, B
vintage Magnetic Bearing
IOMM
Daikin Applied
Centrifugal Chiller Installation,
1033
Operation, and Maintenance
Manual
Navigator Model WWV
Water-cooled Chiller
Daikin Applied
IOM 1264
Installation, Operation, and
Maintenance Manual
MicroTech III chiller
unit controller Protocol
Daikin Applied
ED 15120
Information, L
L
on
LonMark
LonMark
078-0120-
Interoperability
Interoperability Guidelines,
01G
Association
Version 3.4
LonMark
LonMark Application Layer
078-0120-
Interoperability
Interoperability Guidelines,
01G
Association
Version 3.4
LonMark
LonMark Functional Profile:
Interoperability
8040_10
Chiller, Version 1.0
Association
L
on
Echelon
078-0156-
Topology Transceiver Users
Corporation
01G
Guide
www.DaikinApplied.com
W
on
Initial release
Changed OMM 998 to OM 1051. Added
Model AGZ-D
Updated Daikin branding. Added step 1 to
set unit switch=off before installing a new
module. Added AGZ-E and AWV chiller
models, Troubleshooting section, reference
to LonMark 3.4 certification, spec table,
dimensional data, new photos, BSP version,
and formatting changes
Added AMZ chiller model to data tables,
Reference Documents, and other
associated references.
Added WME & WWV chiller models.
Source
Model AWS Air
®
www.
DaikinApplied.
com
www.
DaikinApplied.
com
Model AGZ Air
®
www.
DaikinApplied.
com
www.
DaikinApplied.
com
www.
DaikinApplied.
com
www.
DaikinApplied.
com
www.
DaikinApplied.
W
and
on
orks
com
W
Networks
orks
Layers 1-6
®
www.lonmark.
org
www.lonmark.
org
www.lonmark.
org
W
FTT-10A Free
orks
www.echelon.
com
Limited Warranty
Consult your local Daikin Applied Representative for warranty
details. To find your local Daikin Applied Representative, go to
www.DaikinApplied.com.
orks
Hazardous Information Messages
Recognize Safety Symbols, Words and Labels
The following symbols and labels are used throughout this
manual to indicate immediate or potential hazards. It is the
owner and installer's responsibility to read and comply with
all safety information and instructions accompanying these
symbols. Failure to heed safety information increases the
risk of property damage and/or product damage, serious
personal injury or death. Improper installation, operation and
maintenance can void the warranty.
Cautions indicate potentially hazardous situations, which can result in
personal injury or equipment damage if not avoided.
Static sensitive components. Can cause equipment damage.
Discharge any static electrical charge by touching the bare metal inside the
control panel before performing any service work. Never unplug cables,
circuit board terminal blocks, or power plugs while power is applied to the
panel
Warnings indicate potentially hazardous situations, which can result in
property damage, severe personal injury, or death if not avoided.
Dangers indicate a hazardous situation which will result in death or
serious injury if not avoided. Electric shock hazard. Can cause personal
injury or equipment damage. This equipment must be properly grounded.
Connections and service to the MicroTech III Unit Controller must be
performed only by personnel knowledgeable in the operation of the
equipment being controlled.
This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with this instruction manual,
may cause interference to radio communications. It has been tested and
found to comply with the limits for a Class A digital device, pursuant to
part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a
commercial environment. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be required
to correct the interference at his or her own expense. Daikin disclaims any
liability resulting from any interference or for the correction thereof.
3
IM 968-4 • MICROTECH III CHILLER UNIT CONTROLLER
I
nTroduCTIon
CAUTION
WARNING
DANGER
NOTICE
I
nTroduCTIon