{카테고리_이름} Daikin ALTHERMA에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Daikin ALTHERMA 9 페이지. Low temperature split, eabh16da6v, eabh16da9w, eabx16da6v, eabx16da9w, eavh16s18da6v(g), eavh16s23da6v(g), eavh16s18da9w(g), eavh16s23da9w(g), eavx16s18da6v (g), eavx16s23da6v(g), eavx16s18da9w(g), eavx16s23da9w(g)
Daikin ALTHERMA에 대해서도 마찬가지입니다: 빠른 매뉴얼 (4 페이지), 사용자 설명서 (5 페이지), 사용자 참조 설명서 (20 페이지)

Daikin ALTHERMA 설치 매뉴얼
3 Installation
3
Installation
3.1
Opening the units
3.1.1 To open the outdoor unit
1
Remove 1 screw from the service cover.
2
2
2
Remove the service cover.
3.2

Mounting the outdoor unit

3.2.1 To prepare the installation structure

If the unit is installed directly on the floor, prepare 4 sets of M8 or M10
anchor bolts, nuts and washers (field supply) as follows:
INFORMATION
The maximum height of the upper protruding part of the bolts
is 15 mm.
(mm)
In order to guarantee good operation of the unit in areas with risk of
snowfall, a minimum of 10 cm needs to be assured below the bottom
plate of the unit. It is recommended to construct a pedestal with the
same height as the maximum snowfall height. On this pedestal it is
then recommended to install the EKFT008CA option kit to guarantee
the minimum space of 10 cm below the bottom plate of the unit.
Installation manual
2
1x
1
b
(mm)
a Maximum snowfall height
b EKFT008CA option kit
If the unit is installed on brackets to the wall, it is advised to use the
EKFT008CA option kit and to install the unit as follows:
b
b
(mm)
a Maximum snowfall height
b EKFT008CA option kit
EVLQ05+08CAV3
Daikin Altherma hybrid heat pump – outdoor unit