Anolis ArcSource 140 COB Recessed 사용자 지침 - 페이지 3

{카테고리_이름} Anolis ArcSource 140 COB Recessed에 대한 사용자 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Anolis ArcSource 140 COB Recessed 6 페이지.

Connect the cable to the suitable connection block (8). To pass the cable through the cable gland (9), make an
opening in the blank cable gland (9).
DIP switch
4. DMX and DALI address setting and control
The fixture can be controlled by one of the following method: DMX 512
The DIP switch, located next to the connection blocks, allows to set a DMX address and also allows to switch
the fixture to the update mode in case of software update.
DIP 10 - ON=100W, OFF=140W
DIP 11 - ON=test (full light output)
DIP 12 - change from OFF to ON position switches the fixture to the update mode.
DMX control
The DMX start address, is the first channel used to receive instructions from the DMX controller. The address
may be any channel from 1 to 512.
Example of DMX addresses:
DALI
DMX
Power
DMX control
3
DALI
ArcPixel Power US
(or ArcZone DRS Pixel US)