Anolis ArcSplitter 2x12 사용자 지침
{카테고리_이름} Anolis ArcSplitter 2x12에 대한 사용자 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Anolis ArcSplitter 2x12 3 페이지.
The ArcSplitter 2x2 divides two LED inputs of the ArcPower driver (s) into 2 branches .This unit is de-
signed for interior use and should be connected to the ArcPower (ArcPower/K2) drivers only.
1. Fixture exterior view
- LED input (line A)
2 - LED input (line B)
3 - LED outputs -2 (line A)
4 - LED outputs -2 (line B)
2. Installation
1. Place the ArcSplitter 2x12 on a non-flammable flat surface in any orientation and fixed it with 4 screws. There
are four mounting holes of a diameter of 5 mm in a bottom of the unit housing. It is also possible to install this
unit to the rack after installing two rack holders (enclosed).
2. Connect both unit inputs (),(2) with LED outputs of the ArcPower driver (s).
3. Connect the LED modules to the unit´s outputs (3),(4).If you use all outputs in line A or B, connect the
corresponding link cable (7) or (8) to the socket marked "CABLE TIDY".This socket is not wired, it is only a
"holder" for the link cable to prevent it to hang freely fro mthe unit..
The max. load of each LED output depends on the number of used outputs in the corresponding line (A or
B):
Number of used outputs in one line
2
3
4
5
6
7
8
9
0
2
User instructions
ArcSplitter 2x12
5 - Cable tidy socket (line A)
6 - Cable tidy socket (line B)
7 - Link cable (line A)
8 - Link cable (line B)
Max. load per output
36 LEDs
8 LEDs
2 LEDs
9 LEDs
7 LEDs
6 LEDs
5 LEDs
4 LEDs
4 LEDs
3 LEDs
3 LEDs
3 LEDs