Inlet Sensor Calibration
The inlet sensor calibration does not need to be
as precise as the outlet sensor calibration. As
long as the inlet sensor is reading within 1-2%
of the actual moisture, then it does not need
calibration. This is because the DM510 uses the
change in the inlet moisture value from minute
to minute, not the actual moisture value.
Take a moisture sample.
Estimate the time for product to reach
the inlet sensor from where you took
the sample. Do your bench top test.
Calibrate
Press
when you think the
product has reached the sensor.
Use arrows to highlight "inlet sensor."
Press
Enter
to accept.
Press
Enter
to start the calibration.
When the bench top icon appears on
screen enter your manual test result:
Press
Calibrate
and use arrows to
highlight the sensor with the "sample
waiting" message.
Press
Enter
to select.
Enter your bench top test value and
press
Enter
to accept.
Once the new value has been entered you may
notice a slight change in the inlet moisture read-
ing on the main screen. The maximum change the
DM510 will make with each calibration is 0.5%. If
there is a still a large difference after the calibra-
tion it may be necessary to do additonal samples
to bring the moisture readings into line.
Conditions to go
1. No alarms.
2. Less than 2% difference between
actual moisture and target moisture.
3. Less than 2% difference between
expected moisture and actual moisture.
Alarms & Alarm Limits
Alarms provide an indication of something
requiring attention. Critical alarms will cause
Automatic Operation to be disabled immedi-
ately or after a period of time. Some alarm
conditons will place the system into Local
mode for safety reasons. Select alarm limits
carefully.
Press
Alarms
and then "1" to
Use the arrow keys to highlight the item
Press
Enter
to accept
Use the arrow keys to highlight the limit
to change
Type in the new value
Press
Enter
to accept.
REPEAT as needed for all alarm limits
Press
Alarms
from the main screen,
then "2" to
View Alarms
Use the arrow keys to scroll through
the alarm history.
Cancel
Press
to cancel the alarm sound
Changing the Bin number
Ready
The use of the bin number is optional, but
many sites find it a useful way to track what
goes into their storage bins.
Press
Bin
If the dry bin you have been sending
product to is full, press
Bin Report
Note: This is the final report for this bin.
You will not be able to reprint it. Once
chosen it can not be cancelled. Be sure
the printer is ON and working before
selecting it.
If the Bin you are sending dry product
to is NOT full and you will be adding
product later, press
Set Limits
new bin. The DM510 will remember the
information in the bin, until you use it
again.
Pressing
report for the current bin.
End of Season Checklist
Unplug the printer cable, turn off the
printer, and unplug the cord (place in a
clean location).
Turn off the DM510 (switch at bottom)
Leave the DM510 plugged in to provide
a continued connection to ground.
1
to print the
and then choose a new bin.
2
and choose a
3
will print the interim bin
Full training videos are on the
Dryer Master Media channel