Absolon IRENE BASIC 사용 설명서 - 페이지 5

{카테고리_이름} Absolon IRENE BASIC에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Absolon IRENE BASIC 6 페이지. Autonomous outdoor siren

Absolon IRENE BASIC 사용 설명서
8) Once you find the combination you want, press the MENU button and go into the programming of the
side LEDS. (left right).
9) LED No3 (VERTICAL LED) lights up immediately.
10) Press the SELECT button gradually and choose between 5 different configurations of the side LEDs. (left
& right).
11) After finding the combination you want, press the MENU button.
12) LED No4 (LISTEN SOUND) lights up immediately.
13) Press the SELECT key to hear the sound you successfully saved last.
14) After listening to the sound, press the MENU button.
15) LED No5 (CHECK FLASH) lights up immediately.
16) Press the SELECT key and activate all the side and center LEDs according to the last successful save.
17) After seeing the combination of flashing, press the MENU key continuously for 2 seconds. After hearing
a prolonged "beep", you have exited successfully from programming.
Installation
To install the siren, you have to follow the following steps:
1. Place the siren on a high point where it is not easily accessible, to be safe from sabotage but also visible
from afar.
2. Mount the siren base securely with screws and the corresponding plastic plugs with the help of the
integrated spirit level on the siren's base (back).
3. After screwing the siren, you must pass the connection cable that comes from the alarm panel into the
siren's base and connect the cables to the siren. Then connect the terminals (black & red) to the battery
terminals and proceed with programming.
4. After programming, close the siren / with the tamper cover. The siren enters normal mode, as the
central LEDs start to flash based on the program you selected.
5. When the siren is powered by the alarm panel, it is ready for use.
Siren Reset
To reset the siren to factory settings, press the MENU and SELECT buttons for 3sec at the same time, and
the LEDs will flash as and a confirmation sound will sound. The siren returns to Normal Mode automatically
when it is in standby mode after 1 minute of inactivity.
Battery Change
To perform a service, you must connect the clone of the cable that you have connected to the siren RST
TMP to the alarm panel, at the + 12V of the panel until you change the siren battery. After you finish and
close the siren cover correctly, remove the clone from + 12V. Now the siren has Tamper turned on again.