3 About the system

WARNING
▪ Do NOT pierce or burn refrigerant cycle parts.
▪ Do NOT use cleaning materials or means to accelerate
the defrosting process other than those recommended
by the manufacturer.
▪ Be aware that the refrigerant inside the system is
odourless.
WARNING
Air purging heat emitters or collectors. Before you
purge air from heat emitters or collectors, check if
is displayed on the home screen of the user interface.
▪ If not, you can purge air immediately.
▪ If yes, make sure that the room where you want to
purge air is sufficiently ventilated. Reason: Refrigerant
might leak into the water circuit, and subsequently into
the room when you purge air from the heat emitters or
collectors.
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
3
About the system
Depending on the system layout, the system can:
▪ Heat up a space
▪ Cool down a space (if a heating/cooling heat  pump model is
installed)
▪ Produce domestic hot water (if a DHW tank is installed)
3.1
Components in a typical system
layout
g
C
c
a
b
d
A
Main zone. Example: Living room.
B
Additional zone. Example: Bedroom.
C
Technical room. Example: Garage.
a
Outdoor unit heat pump
b
Indoor unit heat pump
c
Domestic hot water (DHW) tank
d
User interface of the indoor unit
e
User interface used as room thermostat
f
Underfloor heating
g
Radiators, heat pump convectors, or fan coil units
Operation manual
4
or
B
A
e
f
4

Operation

4.1

User interface: Overview

The user interface has the following components:
a
Status indicator
b
LCD screen
c
Dials and buttons
Status indicator
The LEDs of the status indicator light up or blink to show the
operating mode of the unit.
LED
Mode
Blinking blue
Standby
Continuous blue Operation
Blinking red
Malfunction
LCD screen
The LCD screen has a sleeping function. After 15  min of non-
interaction with the user interface, the screen darkens. Pressing any
button or rotating any dial awakens the display.
Dials and buttons
You use the dials and buttons:
▪ To navigate through the screens, menus and settings of the LCD
screen
▪ To set values
a
b
c
d
Item
a Left dial
The LCD shows an arc on the left side of the
display when you can use the left dial.
: Turn, then press the left dial. Navigate
through the menu structure.
: Turn the left dial. Choose a menu item.
: Press the left dial. Confirm your choice
or go to a submenu.
b Back button
: Press to go back 1 step in the menu structure.
c Home
: Press to go back to the home screen.
button
a
b
c
Description
The unit is not in operation.
The unit is in operation.
A malfunction occurred.
See
"7.1 To display the help text
malfunction" [ 4  14]
in case of a
for more information.
e
Description
EHVZ04+08S18+23EA6V+9W
Daikin Altherma 3 R F
4P629089-1 – 2020.08